Abstract
Simulation processes and an experimental test are performed to investigate the practicability of using the time domain reflectometry (TDR) for the detection of defects in pipelines. Similar to the employment of TDR in checking electrical wiring it may serve to evaluate the position and the degree of a defect. Various simulation models are used to learn about the correlation between the quality of the defect and the reflected signals. A simplified laboratory model is set up for conducting trials with a TDR measurement device. Especially for online monitoring of horizontal pipeline drillings the method could provide an improvement over conventional approaches.
| Titel in Übersetzung | Fault locating in pipelines via time domain reflectometry |
|---|---|
| Originalsprache | Deutsch |
| Fachzeitschrift | Logistics Journal |
| Jahrgang | 2016 |
| DOIs | |
| Publikationsstatus | Veröffentlicht - 27 Mai 2016 |
Schlagwörter
- Fault locating
- Pipeline monitoring
- Pulling process
- TDR
- Time domain reflectometry
ASJC Scopus Sachgebiete
- Management-Informationssysteme
- Steuerungs- und Systemtechnik
- Managementlehre und Operations Resarch
Dieses zitieren
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver