Abstract
A rinsing-technique with a spraying gun in combination with the ATP-bioluminescence for determining the microbial load was investigated. In each case 3.8-cm2 pig-rind was rinsed with buffered peptone water using a modified sprinkle-bottle. The sample-suspensions were gathered in a one-way syringe and sent through a filter cascade consisting of a coarse filter in order to remove bigger particles and a sensitive filter to attach the micro-organisms as well as somatic cells. This procedure was followed by an extraction of the ATP from the sensitive filter with CellSolver FBC-solution. The destructively gained samples were determined on their TVC by the conventional method. Results of the carcass-surface spray test combined with bioluminescence compared to the conventional destructive method followed by plate-count showed a correlation r=0.93 with a detection limit down to 104 cfu/cm2.
| Original language | English |
|---|---|
| Pages (from-to) | 165-168 |
| Number of pages | 4 |
| Journal | Meat science |
| Volume | 59 |
| Issue number | 2 |
| E-pub ahead of print | 11 Jul 2001 |
| DOIs | |
| Publication status | Published - Oct 2001 |