Two-photon fluorescence microscopy for determination of the riboflavin concentration in the anterior corneal stroma when using the dresden protocol

  • Theo Seiler
  • , Tobias Ehmke
  • , Isaak Fischinger
  • , Daniel Zapp
  • , Oliver Stachs
  • , Theo Seiler
  • , Alexander Heisterkamp

Research output: Contribution to journal › Article › Research › peer review

Abstract

PURPOSE. To determine the riboflavin concentration gradient in the anterior corneal stroma when using the Dresden protocol with different dextran solutions. METHODS. Three different groups of porcine corneas, five each, were compared regarding the riboflavin concentration in the anterior stroma. Before all experiments, stable hydration conditions were established for the corresponding solution. All groups were treated with 0.1% riboflavin in different dextran solutions (15%, 16%, 20%). After imbibition, two-photon microscopy was used to determine fluorescence intensity. For signal attenuation and concentration determination corneas were saturated and measured a second time by twophoton microscopy. Additionally, the distribution was calculated mathematically and compared to the empiric results. RESULTS. Riboflavin concentration is decreasing with depth for all dextran solutions. A nearly constant concentration could be determined over the first 75 lm. Analysis of the fit functions leads to diffusion coefficients of D = 2.97 × 10-7 cm2/s for the 15% dextran solution, D = 2.34 × 10-7 cm2/s for the 16% dextran solution, and D = 1.28 × 10-7 cm2/s for the 20% dextran solution. The riboflavin gradients of the 20% dextran group were statistically significantly different from 15% dextran starting at a depth of 220 mm and deeper (P = 0.047). The 16% dextran group differed statistically at a depth of 250 µm and deeper (P = 0.047). These results show a significant difference to those published previously. CONCLUSIONS. With correct settings two-photon microscopy is a precise way to determine the concentration of riboflavin in cornea. The measured gradient is excellently fit by a Gaussian distribution, which comes out as a solution of Fick’s second law.

Original languageEnglish
Pages (from-to)6740-6746
Number of pages7
JournalInvestigative Ophthalmology and Visual Science
Volume56
Issue number11
DOIs
Publication statusPublished - Oct 2015

Keywords

  • Concentration
  • Cornea
  • Cross-linking
  • Riboflavin distribution
  • Two-photon microscopy

ASJC Scopus subject areas

  • Ophthalmology
  • Sensory Systems
  • Cellular and Molecular Neuroscience

Cite this